Melatonin Direct RIA
1. Introduction
1.1 Intended use and principle of the test
125I – Radioimmunoassay for the direct quantitative determination of melatonin in human serum and
plasma.
The assay procedure follows the basic principle of radioimmunoassay, involving competition between a
radioactive and a non-radioactive antigen for a fixed number of antibody binding sites. When the system
is in equilibrium, the antibody bound radioactivity is precipitated with a second antibody in the presence
of polyethylene glycol. After centrifugation and decantation of the supernatant the precipitate is counted
in a gamma counter. The amount of 125I-labelled antigen bound to the antibody is inversely proportional
to the analyte concentration of the sample. Quantification of unknown samples is achieved by comparing
their activity with a reference curve prepared with known standards.
1.2 Clinical application
In mammals, melatonin is biosynthesized in the pineal gland from the essential dietary amino acid
tryptophan, with serotonin produced as an intermediate. In general melatonin acts as an endocrine
hormone playing a key role in the regulation of the biorhythm.
The serum and saliva melatonin levels in humans show a marked circadian rhythm characterized by very
low levels during day time and high levels during night time.
Altered patterns and/or levels of melatonin secretion have been reported to coincide with sleep disorders,
jet lag, depression, stress, schizophrenia, hypothalamic amenorrhea, pregnancy, anorexia nervosa, some
forms of cancer, immunological disorders as well as control of sexual maturation during puberty.
Many biological effects of melatonin are generated through activation of melatonin receptors, while others
are due to its role as a powerful scavenger for free radicals in the human body.
Therapeutic consequences should never be based on laboratory results alone even if all test results are in
agreement with the items as under point “Procedural cautions, guidelines and warnings”. Any laboratory
result is only a part of the total clinical picture of the patient.
Only in cases where the laboratory results are in an acceptable agreement with the overall clinical picture
of the patient it can be used for therapeutic consequences.
The test result itself should never be the sole determinant for deriving any therapeutic consequences.
2. Procedural cautions, guidelines, warnings and limitations
2.1 Precautions, guidelines and warnings
(1) This kit is intended for professional use only. Users should have a thorough understanding of this protocol
for the successful use of this kit. Only the test instruction provided with the kit is valid and has to be used
to run the assay. Reliable performance will only be attained by strict and careful adherence to the
instructions provided.
(2) This assay was validated for certain types of samples as indicated in Intended Use (please refer to
Chapter 1). Any off-label use of this kit is in the responsibility of the user and the manufacturer cannot be
held liable.
(3) Reagents of this kit which contain human serum or plasma have been tested and confirmed negative for
HIV I/II, HBsAg and HCV by approved procedures. All reagents, however, should be treated as potential
biohazards in use and for disposal.
(4) The principles of Good Laboratory Practice (GLP) have to be followed.
(5) In order to reduce exposure to potentially harmful substances, wear lab coats, disposable protective
gloves and protective glasses where necessary.
(6) All kit reagents and specimens should be brought to room temperature and mixed gently but thoroughly
before use. Avoid repeated freezing and thawing of reagents and specimens.
(7) For the dilution or reconstitution purposes use deionized, distilled or ultra-pure water.
(8) The radioactive material (125Iodine, half life 60 days, emitting ionizing X-radiation with 28 keV and Gradiation
with 35.5 keV) may be received, acquired, possessed and used only by physicians, laboratories
or hospitals. In compliance with regulations, a copy of the customer’s current radioisotope license must
be on file with the supplier. Orders cannot be shipped until the license is received by the supplier
(Radiation Protection Act of June 30, 1989).
(9) Duplicate determination of sample is highly recommended to be able to identify potential pipetting errors.
(10) Once the test has been started, all steps should be completed without interruption. Make sure that the
required reagents, materials and devices are prepared ready at the appropriate time.
(11) Incubation times do influence the results. All tubes should be handled in the same order and time
intervals.
English
Version: 13.0 Effective: 2015-01-14 3/13
(12) To avoid cross-contamination of reagents, use new disposable pipette tips for dispensing each reagent,
sample, standard and control.
(13) A standard curve must be established for each run.
(14) The controls should be included in each run and fall within established confidence limits. The confidence
limits are listed in the QC-Report.
(15) Do not mix kit components with different lot numbers within a test and do not use reagents beyond
expiry date as shown on the kit labels.
(16) Some reagents contain sodium azide (NaN3) as preservative. In case of contact with eyes or skin, rinse
off immediay with water. NaN3 may react with lead and copper plumbing to form explosive metal
azides. When disposing reagents, flush with a large volume of water to avoid azide build-up.
(17) For information on hazardous substances included in the kit please refer to Material Safety Data Sheet
(MSDS). The Material Safety Data Sheet for this product is available directly on the website of the
manufacturer or upon request.
(18) The expected reference values reported in this test instruction are only indicative. It is recommended that
each laboratory establishes its own reference intervals.
(19) The results obtained with this test kit should not be taken as the sole reason for any therapeutic
consequence but have to be correlated to other diagnostic tests and clinical observations.
(20) Kit reagents must be regarded as hazardous waste and disposed according to national regulations.
2.2 Limitations
Any inappropriate handling of samples or modification of this test might influence the results.
2.2.1 Interfering substances
Plasma/Serum
Samples containing precipitates or fibrin strands or which are haemolytic or lipemic might cause
inaccurate results.
2.2.2 Drug interferences
There are no known substances (drugs) which ingestion interferes with the measurement of melatonin
level in the sample.
2.2.3 High-Dose-Hook effect
No hook effect was observed in this test.
3. Storage and stability
Store the unopened reagents at 2 - 8 ?C until expiration date. Do not use components beyond the expiry
date indicated on the kit labels. Once opened the reagents are stable for 1 month when stored at
2 – 8 °C.
Melatonin is sensitive to light-exposure. To avoid photo-oxidative reduction of melatonin, it is necessary
to keep it away from direct sunlight and from heat.
4. Materials
4.1 Content of the kit
BA R-0028 Equalizing Reagent - Lyophilized
Content: Human serum, negative for HIV I/II, HBsAg and HCV
Volume: 2 vials, dark green cap
BA R-0030 Precipitating Reagent - Ready to use
Content: Goat anti-rabbit serum in PEG phosphate buffer
Volume: 2 x 55 ml/vial, yellow cap
BA R-3310 Melatonin Antiserum - Ready to use
Content: Rabbit anti-melatonin antibody, blue coloured
Volume: 1 x 5.25 ml/vial, blue cap
Version: 13.0 Effective: 2015-01-14 4/13
Standards and Controls - Ready to use
Cat. no. Component Colour/Cap Concentration
pg/ml
Concentration
pmol/l
Volume/
Vial
BA R-3301 white 0 0 4 ml
BA R-3302 light yellow 3 12.9 4 ml
BA R-3303 orange 10 43 4 ml
BA R-3304 dark blue 30 129 4 ml
BA R-3305 light grey 100 430 4 ml
BA R-3306 black 300 1 290 4 ml
BA R-3307 brown 1 000 4 300 4 ml
BA R-3351 light green Refer to QC-Report for expected value and
acceptable range!
4 ml
BA R-3352 dark red 4 ml
Conversion: Melatonin (pg/ml) x 4.30 = Melatonin (pmol/l)
Content: TRIS buffer with non-mercury preservatives, spiked with defined quantity of melatonin
BA R-3313 Assay Buffer - Ready to use
Content: TRIS buffer
Volume: 1 x 15 ml/vial, light purple cap
Hazards
identification:
H315 Causes skin irritation.
H319 Causes serious eye irritation.
BA R-3315 Enzyme - Lyophilized
Content: Digestive enzyme
Volume: 4 vials, pink cap
BA R-3316 Enzyme Buffer - Ready to use
Content: 1 M hydrochloric acid
Volume: 1 x 15 ml/vial, orange cap
BA R-3320 125I – Melatonin - Ready to use
Content: 125I labeled Melatonin, red coloured
Volume: 1 x 3 ml/vial, red cap
Hazards
identification:
Radioactive, activity < 200 kBq
4.2 Additional materials and equipment required but not provided in the kit
? Calibrated precision pipettes to dispense volumes between 15 - 1000 μl; 3 ml, 10 ml
? Conical plastic tubes (polypropylene, polystyrene) and suitable rack
? Centrifuge (preferable refrigerated) capable of at least 3 000 x g
? Suitable device for aspirating or decanting the tubes
? Vortex mixer
? Gamma counter
? Water (deionized, distilled, or ultra-pure)
? Absorbent material (paper towel)
5. Sample collection and storage
The test should be performed with serum or EDTA-plasma samples.
Haemolytic and lipemic samples should not be used with this assay. The samples can be stored for up to
24 hours at 2 - 8 °C or for a longer period (up to 6 months) at -20 °C. Repeated freezing and thawing
should be avoided.
Version: 13.0 Effective: 2015-01-14 5/13
Serum
Collect blood by venipuncture (Monovette™ or Vacuette™ for serum), allow to clot, and separate serum
by centrifugation following manufacturer’s instructions . Do not centrifuge before complete clotting has
occurred. Patients receiving anticoagulant therapy may require increased clotting time.
Plasma
Whole blood should be collected into centrifuge tubes containing EDTA as anti-coagulant (Monovette™ or
Vacuette™) and centrifuged following manufacturer’s instructions immediay after collection.
6. Test procedure
Allow all reagents - with the exception of Precipitating Reagent - to reach room temperature and mix
thoroughly by gentle inversion before use. Number the assay tubes accordingly. Duplicate determinations
are recommended.
Pipetted liquids should not adhere to the wall of the RIA tubes. If necessary please centrifuge the tubes
for 1 minute at 500 x g to spin down adhering liquids.
For the assay the use of conical tubes is highly recommended.
6.1 Preparation of reagents
Enzyme Solution
Reconstitute the content of the vial with 3 ml of Enzyme Buffer prior to use. Mix by vortexing and leave it
30 minutes on a rotating mixer (please make sure that the lyophilisate is dissolved compley!). The
reconstituted enzyme solution cannot be stored and can only be used once. Upon request additional
Enzyme vials are provided.
Equalizing Reagent
The Equalizing Reagent has to be reconstituted with 10 ml water (deionized, distilled, or ultra-pure).
Reconstituted Equalizing Reagent which is not used immediay has to be frozen for max 1 month at
-20 ?C (in aliquots) and may be thawed only once.
6.2 Melatonin RIA
1. Pipette 15 μl of standards and controls into the respective tubes.
2. Pipette 150 μl of Equalizing Reagent into the tubes for NSB, standards and controls.
3. Pipette 150 μl of the samples into the respective tubes.
4. Add 50 μl of Enzyme Solution (refer to 6.1) to all tubes (except totals) and vortex.
5. Incubate for 1 h at RT (20 - 25 °C).
6. Pipette 100 μl of Assay Buffer into all tubes (except totals) and mix shortly.
7. Pipette 25 μl of the 125I Melatonin into all tubes.
8. Pipette 50 μl of Melatonin Antiserum into all tubes (except totals and NSB); mix thoroughly.
9. Cover tubes. Incubate for 20 - 24 h at RT (20 - 25 °C).
10. Mix the chilled (2 - 8 °C) Precipitating Reagent thoroughly, pipette each 1000 μl into all tubes
(except totals), and mix on a vortex.
11. Incubate for 20 min at 2 - 8 °C.
12. Centrifuge for 20 min at 3 000 x g, if possible in a refrigerated centrifuge.
13. Decant or aspirate the supernatant carefully (except totals). Blot the tubes dry and leave them
upside for 2 minutes.
14. Count all tubes for 1 min in a gamma counter.
Version: 13.0 Effective: 2015-01-14 6/13
7. Calculation of results
Measuring range
Melatonin
2.3 – 1 000 pg/ml
Subtract the mean cpm of the non-specific binding NSB from the mean cpm of standards, controls and
samples.
The standard curve from which the concentrations in the samples can be read off, is obtained by plotting
the percentage of (B-NSB)/ (B0-NSB) measured for the standards (linear, y-axis) against the
corresponding standard concentrations (logarithmic, x-axis).
Use a non-linear regression for curve fitting (e.g. spline, 4- parameter, akima).
The concentrations of the samples and controls can be read directly from the calibration curve.
Samples found with concentrations higher than the highest standard (Standard G) should be diluted
accordingly with Equalizing Reagent (BA R-0028) and have to be re-assayed.
Conversion
Melatonin (pg/ml) x 4.30 = Melatonin (pmol/l)
Expected reference ranges
The reference concentration given below should be taken as a guideline only. It is recommended that
each laboratory should establish its own reference ranges.
The melatonin concentrations depend on age and on a circadian rhythm with a maximum at night
between 1.00 and 3.00 a.m. This maximum is usually clearly higher than the values during the daytime.
The melatonin levels in humans show a marked circadian rhythm characterized by very low levels during
day time (up to 30 pg/ml for serum) and high levels during night time (up to 150 pg/ml for serum). The
highest concentrations are found with infants up to the age of 3 years.
7.1 Quality control
It is recommended to use control samples according to national regulations. Use controls at both normal
and pathological levels. The kit or other commercial controls should fall within established confidence limits.
The confidence limits of the kit controls are indicated on the QC-Report.
7.2 Typical standard curve
Example, do not use for calculation!
Melatonin
B/B0 (%)
pg/ml
8. Assay characteristics
Analytical Sensitivity
(Limit of Detection) 2.3 pg/ml
Version: 13.0 Effective: 2015-01-14 7/13
Analytical Specificity
(Cross Reactivity)
Substance Cross Reactivity (%)
Melatonin
Melatonin 100
N-Acetylserotonin 0.98
5-Methoxytryptophol 0.11
5-Methoxytryptamine 0.07
6-Methoxytryptamine ? 0.01
5-Methoxyindol-3-acetic acid ? 0.01
Serotonin ? 0.01
DL-Tryptophan ? 0.01
DL-5-Methoxytryptophan ? 0.01
5-Hydroxy-L-Tryptophan ? 0.01
Precision
Intra-Assay Inter-Assay
Sample Range (pg/ml) CV (%) Sample Range (pg/ml) CV (%)
Melatonin 1 19.2 ± 1.9 9.8 Melatonin 1 29.4 ± 2.4 8.0
2 41.8 ± 4.0 9.7 2 73.9 ± 8.1 10.9
3 126 ± 16.9 13.4 3 154 ± 20.6 13.3
Linearity Range Mean (%) Range (%)
8.5 – 529 pg/ml 89 82 – 102
Recovery
Range Mean (%) Range (%)
Serum 19.7 – 808 pg/ml 90 70 - 107
Plasma 19.4 - 770 pg/ml 92 79 - 113
9. References/Literature
(1) Melatonin and omentin: influence factors in the obstructive sleep apnoea syndrome? Journal of
Physiology and Pharmacology, 64(3):353-360 (2014)
(2) Robeva et al. Decreased Daily Melatonin Levels in Women with Systemic Lupus Erythematosus - A Short
Report. Balkan Medical Journal, 30: 273-276 (2013)
(3) Gonciarz et al. Plasma insulin, leptin, adiponectin patients treated with melatonin, resistin, ghrelin, and
melatonin in nonalcoholic steatohepatitis. Journal of Pineal Research, 54(2):154-161 (2013)
For updated literature or any other information please contact your local supplier.
Symbols:
Storage
temperature Manufacturer
Contains sufficient for
<n> tests
Expiry date
Batch code
For in-vitro diagnostic
use only!
Consult instructions
for use Content
CE labelled
Caution
Catalogue
number
For research use
only!
Version: 13.0 Effective: 2015-01-14 8/13
Melatonin Direct RIA
1. Einleitung
1.1 Verwendungszweck und Testprinzip
125 I – Radioimmunoassay zur direkten quantitativen Bestimmung von Melatonin in humanem Serum und
Plasma.
Die Testdurchführung folgt den Grundprinzipien eines Radioimmunoassays. Radioaktiv markiertes Antigen
und nicht markiertes Antigen binden kompetitiv an eine definierte Anzahl von Antikörperbindungsslen.
Nach Gleichgewichtseinslung werden die Antigen-Antikörper-Komplexe mit einem zweiten Antikörper in
Anwesenheit von PEG gefällt. Das Präzipitat wird nach Zentrifugieren und Dekantieren oder Absaugen des
Überstands in einem Gamma-Counter gemessen. Die Menge an radioaktiv gebundenem Antigen ist
indirekt proportional zur Antigenkonzentration der Probe.
Die Konzentrationen der unbekannten Proben werden mit Hilfe einer Standardkurve und Abgleich der
gemessenen Aktivitäten ermitt.
1.2 Klinische Anwendung
Das Hormon Melatonin spielt eine Schlüsselrolle in der Regulation des Biorhythmus und wird in der
Zirbeldrüse aus dem Vorläufermolekül Serotonin produziert. Sowohl in Saliva als auch in Serum spiegelt
die Melatoninkonzentration den circadianen Rhythmus wider. Tagsüber ist der Melatoninspiegel niedrig
während er nachts um ein vielfaches ansteigt.
Der Einfluss von Melatonin im Menschen wird in der Literatur mit Schlafstörungen, Jetlag, Depression,
Stress, Schizophrenie, Ausbleiben der Regelblutung, Schwangerschaft, Magersucht, immunologischen
Erkrankungen und in der Kontrolle der sexuellen Reifung in der Pubertät beschrieben.
Viele biologische Effekte von Melatonin verlaufen über die Aktivierung des Melatoninrezeptors. Des
Weiteren dient es im menschlichen Körper als direkter Fänger von freien Radikalen.
Therapeutische Konsequenzen dürfen niemals allein auf Grund von Laborwerten herangezogen werden,
auch wenn diese Werte in Übereinstimmung mit den Qualitätskriterien der Methode beurteilt werden.
Jedes Laborergebnis trägt immer nur zu einem Teil des klinischen Bildes bei.
Nur wenn die Laborergebnisse in akzeptabler Übereinstimmung mit dem klinischen Gesamtbild stehen,
dürfen daraus therapeutische Konsequenzen abgeleitet werden.
Die Laborwerte selbst dürfen niemals der alleinige Grund für daraus abgeleitete therapeutische
Konsequenzen sein.
2. Verfahrenshinweise, Richtlinien, Warnungen und Anwendungsgrenzen
2.1 Verfahrenshinweise, Richtlinien und Warnungen
(1) Dieses Kit ist nur für den gewerblichen Gebrauch. Für eine erfolgreiche Anwendung dieses Kits benötigen
die Anwender ein umfassendes Verständnis dieses Protokolls. Einzig die im Kit enthaltene Testanleitung
ist gültig und bei der Durchführung des Assays zu verwenden. Für eine zuverlässige Leistung müssen die
mitgelieferten Anweisungen genau und sorgfältig befolgt werden.
(2) Dieser Assay wurde für die unter Verwendungszweck (siehe Kapi 1) angegebenen Probenarten
validiert. Jede nicht zugelassene Anwendung dieses Kits obliegt der Verantwortung des Anwenders und
entbindet den Hersler von jeglicher Haftung.
(3) Die humanes Serum oder Plasma enthaltenden Reagenzien des Kits wurden mit geprüften Verfahren auf
HIV I/II, HBsAg und HCV getestet und als negativ bestätigt. Dennoch sollten sämtliche Reagenzien bei
der Handhabung und Entsorgung als potenzielle biologische Gefahrstoffe behandelt werden.
(4) Die Grundsätze der Guten Laborpraxis (GLP) sind zu befolgen.
(5) Bei Bedarf Laborkit, geeignete Einweghandschuhe und Schutzbrille tragen, um die Exposition
gegenüber potenziell gesundheitsgefährdenden Stoffen zu reduzieren.
(6) Alle Reagenzien des Kits sowie die Proben sollten vor der Verwendung auf Raumtemperatur gebracht und
vorsichtig aber gründlich gemischt werden. Wiederholtes Einfrieren und Auftauen von Reag

主站蜘蛛池模板: 舟舟宝贝少儿培训网-少儿艺术培训-少儿舞蹈培训-少儿英语培训 | 嘉兴中诚环保科技股份有限公司_PVC_润滑剂_抗氧剂_辅助热稳定剂 嘉兴市南湖斋食品股份有限公司_南湖斋 | 耐压测试仪(检测电气设备绝缘性能)百科 | 全降解塑料厂家_淋膜_秸秆_手机壳_气泡袋_牙刷牙线_GRS可回收包装材料-东莞全球环保科技有限公司 | 爬架网@建筑爬架网@冲孔建筑爬架网片@工地冲孔建筑爬架网片@工地冲孔建筑爬架网片厂家@工地冲孔建筑爬架网片生产厂家-安平县诺德金属制品有限公司 | 种植槽系统,移动苗床,多层种植货架,潮汐苗床,物流苗床,潮汐面板,立体旋转育秧床,河北博超温室设备有限公司 | 潍坊亿宏重工机械有限公司,破碎机,高性能立磨机,颚式破碎机,锤式破碎机反击式破碎机,重锤式破碎机,高性能反击式破碎机,圆锥式破碎机,给料机系列,链板给料机系列,简易给料机系列,振动给料机 | 生物除臭_废气处理_玻璃钢风机_布袋除尘_脱硫脱硝_催化燃烧_生物滤池_广东正州环保科技股份有限公司 | 万通汽车学校,汽车学校,汽修学校,汽修培训学校,汽车美容学校,汽车维修学校,学汽修-武汉万通汽车学校官方网站 | 三轴伺服机械手_五轴伺服机械手_注塑机械手_东莞市浩能自动化机械有限公司 | 淮南网站制作丨淮南做网站丨淮南网络公司丨淮南哪家网络公司好丨淮南智讯网络 | 讨债公司_要债公司_要账公司[18年讨债要债经验]讨账公司 | 乌兰察布市集宁牧田饲料科技有限公司-乌兰察布奶牛饲料|饲料原料加工|精品羊料 | 性激素6项实验检测,放射免疫实验检测,明胶酶谱试剂盒,科研用人血清,质控标品,试剂盒-南京信帆生物技术有限公司 | 军用笔记本电脑_三防加固笔记本电脑_平板型全坚固计算机-集海卫通 | 网带窑,催化剂网带窑,电热回转窑-淄博圣元窑炉工程有限公司 | 中陕核二一〇研究所有限公司| 悬挂式小鼠笼架,植物标本采集箱,昆虫标本盒厂家-北京合力科创科技发展有限公司 | 深圳市桃子自动化科技有限公司-点胶机_灌胶机_焊锡机_螺丝机_SCARA机器人 | 四川方法数码科技有限公司 | 喷涂陶瓷涂层_热喷涂陶瓷涂层-北京耐默公司 | 思为网络_成都百度优化快照排名-成都网站建设优化_成都网页设计_成都SEO公司 | 液位变送器_智能压力变送器_3051差压变送器_单双法兰,投入式,电容式,温度变送器-淮安润中仪表科技有限公司 | 重庆晓宇餐饮文化管理有限公司_重庆晓宇火锅 | 云南万通汽车学校【官方网站】 | 叛逆孩子改造,青少年行为矫正,戒网瘾学校,特训学校,全封闭军事化管理学校 | 线路板生产厂家|电路板快板打样|PCB工厂价格|江西锦宏电子有限公司|PCB版加工定制 | 恒温干燥箱厂家-烘箱厂家-马弗炉厂家-生化培养箱-上海有丰科学仪器有限公司 | 聚丙烯酰胺,聚合氯化铝,重金属捕捉剂,污泥调理剂,活性氧化铝,生石灰,反渗透阻垢剂,工业葡萄糖,硫酸铝,果壳活性炭,柱状活性炭,蜂窝活性炭,石英砂,锰砂-北京雁归来环保科技有限公司-以真诚为立足之本,以质量为生存之本,愿与海内外同仁共创双赢。雁归来人一路走来,气贯长虹,勇锐盖过怯弱,进取压倒苟安!我们紧扣时代脉搏,专注水处理、继往开来! | 转炉烟道,转炉汽化冷却烟道,转炉汽化烟道,汽化冷却烟道系统生产厂家-宏发制造集团有限公司原河北宏发机械有限公司 | 汽车漆|汽车油漆|工业油漆涂料|汽车漆加盟-佛山市科涂涂料有限公司 | 重庆晓宇餐饮文化管理有限公司_重庆晓宇火锅 | 木材粉碎机,树枝粉碎机,木材破碎机厂家| 廊坊保安公司_廊坊市万帮保安服务有限公司 | 鹰潭代理记账公司_鹰潭代理记账_鹰潭注册公司-鹰潭市新知会计服务有限公司 | 销售系统_营销系统_自动营销软件_b2b营销系统_数字营销平台_AI销售 | 郑州环球重工机械有限公司建筑垃圾处理专题网站 | 医疗器械,理化实验室设备,微生物,培养基,一站式采购 - 杭州润泽仪器商城 | 专业制造泥浆泵阀箱、锻造零件、曲轴、台阶轴等各种机械部件 - 四川中宇重工科技有限公司 | 硫酸、硫酸铵、氯磺酸、氯化亚砜、硫酸钾、对位酯生产销售 - 河北和合化工有限公司 | 展会设计搭建-展厅设计施工公司-展位展台设计搭建-深圳鼎泰展览 展柜设计定制-品牌展柜订做-展柜制作厂家「广州嘉艺展柜」 |